Charming aerial view of Chinon's traditional rooftop architecture in France, highlighting historic urban scenery.

Chimney Chase Cover Replacement in Carson Before Rust Lets Rain In

Pricing Chimney Chase Cover?

Firebox Measured Before Any Quote
Options Priced Side by Side
Written Quote Before Work
Photos in Every Report
Based in Carson
Firebox Measured Before Any Quote
Options Priced Side by Side
Written Quote Before Work
Photos in Every Report
Based in Carson

What Kemp Does on This Job

Framed chimneys, common on houses with a factory-built fireplace, are closed at the top by a metal pan. Thin galvanized pans rust, hold water and drip into the chase. We measure the chase, have a stainless cover made with crossed bends so water runs off, and seal it around the flue pipe. If you plan a new gas unit in that chase, we size the cover opening for its vent.

Chase measured on all four sides
Stainless cover made to those numbers
Crossed bends so water runs off
Pipe opening sealed against rain
Vent opening sized for a planned gas unit

How chase covers fail on factory-built chimneys

Many homes in Carson, Long Beach and the later tracts in Compton and South Gate do not have a brick chimney at all. They have a factory-built fireplace, a steel box framed into a wall, with a metal flue pipe that runs up through a wooden enclosure on the outside of the house. That enclosure is finished to match the house, and at its top sits a flat sheet of metal with a hole for the flue pipe. The sheet is the only thing keeping rain out of the whole box. Builders often used thin galvanized steel, cut flat or nearly flat, and over time it holds puddles, rusts through, and sags in the middle. Rust streaks run down the siding, water drips into the firebox, and the wood framing inside the enclosure starts to rot. Near the coast, marine air speeds the rust. By the time a stain shows inside, the cover has usually been failing for years.

A replacement starts with a look from the roof and, where we can, inside the enclosure. On the list: the cover itself, the metal flue, the ring that seals the gap around that flue, its cap, and the wood frame underneath. Then we measure the top of the enclosure so the new cover can be made to fit. Our covers are stainless steel, sloped or cross-broken from the center so water runs off instead of pooling, with a drip edge bent down past the siding on every side. A fresh sealing ring goes around the flue pipe. The written quote lists the cover, the collar, any cap replacement and any framing repair, with photos of the old cover and what lies beneath it. Chase covers are priced in writing after we measure, since each enclosure has its own size.

Chase covers and upgrading a factory-built fireplace

A chase cover visit often leads to a bigger question: is the factory-built fireplace below worth keeping? These units are tested and listed as a system, firebox and flue together, and they do wear out. Panels crack, the steel box rusts where water has dripped in, and the flue pipe can separate at its joints. If the inspection shows the fireplace is worn past saving, we lay out the options side by side. You can repair what is listed for that model. You can replace it with a new factory-built wood unit in the same frame. Or you can switch to a sealed gas unit, which can often vent through the same enclosure or straight through the wall. A direct-vent gas fireplace placed where none stood before runs $4,300 to $8,600, and a replacement in the same frame is priced in writing once we know the model.

Whatever you choose for the fireplace, the cover should not wait. Rot in the enclosure framing is the expensive part of a chase cover failure, and it grows each winter the cover stays rusted. If you are selling, a new cover and a clean bill on the framing remove one of the easier items for a buyer's inspector to flag. If you manage townhomes or condos where several units share the same design, we can measure and price every cover on one visit and write a single report for the board. Book through the contact form and tell us what the outside of your chimney looks like, whether it is sided, stuccoed or shingled, and where any water has shown up inside. If you know the make of the fireplace, add that too, since it tells us which replacement parts and units are listed for it.

How Kemp Prices and Plans

Measured First

Firebox and flue sizes taken before any figure

Side by Side

Repair and upgrade priced on one page

Written Lines

Each part of the job listed on its own

Photo Record

Before and after pictures in your report

Towns where Kemp books chimney chase cover

Open a town for its housing notes, codes and the local version of this job.

Full town list

Nothing matched. Try the next town over.

Other Kemp Jobs

Chimney Sweep

Brushing and vacuuming the flue, plus a written note on whether the chimney could take an insert or a steel liner later.

Details

Chimney Inspection

An NFPA 211 look at flue, crown and damper, with each finding ranked and an upgrade path noted where one makes sense.

Details

Chimney Repair

Fixing the chimney parts that let heat, water or smoke out where they should not, priced line by line before work starts.

Details

Fireplace Inspection

The room side of the fireplace checked: firebox, throat, damper, hearth and the clearances an insert would have to meet.

Details

Fireplace Repair

Firebrick, refractory panels, throat and hearth put right, or a plain note on when an insert would make more sense.

Details

Chimney Level 2 Inspection

Every flue filmed end to end, attic and roof looked over too, before a sale, an appliance change or after a quake.

Details

Chimney Cap Installation

A stainless cap with spark mesh, sized to the flue tile, or to the new liner when an insert goes in.

Details

Chimney Flashing Repair

Water at the roof joint tracked to its source, then step and counter metal renewed to suit your roofing.

Details

Chimney Masonry Repair

Open joints repointed, spalled brick swapped and the stack made tight before any liner or insert goes inside it.

Details

Chimney Rebuilds

A stack that has failed taken down and laid again, with the new flue planned around the heater you intend to run.

Details

Fireplace Cleaning

Ash, soot and film cleared from the firebox, doors and hearth, plus a look at whether the opening would take an insert.

Details

Gas Fireplace Cleaning

A gas fireplace or insert serviced from pilot to glass, then lit so flame and venting can be checked.

Details

Gas Fireplace Repair

Gas fireplaces and inserts that will not light, stay lit or hold a steady flame traced to the failed part and repaired.

Details

Fireplace Remodel

A new surround, mantel and hearth built around the heater you choose, with the insert or gas unit planned in first.

Details

Fireplace Inserts

Wood, gas and pellet inserts sized to your firebox and room, vented through a steel liner, and installed as a planned job.

Details

Pellet Stove Repair

Pellet stoves and inserts that refuse to light, go out mid-burn or soot the glass, cleaned and tested part by part.

Details

Wood Stove Repair

Freestanding stoves and wood inserts brought back to a hot, steady burn, with a straight answer when replacing costs less.

Details

Gas Logs

Vented gas log sets matched to the opening and the room, with the gas line and valve fitted and the flame tuned.

Details

Chimney Seismic Retrofit

Brick chimneys tied back to the house frame or cut down and finished lighter, planned before an insert goes in.

Details

Chimney Crown Repair

The concrete slab on top of the chimney sealed or poured again, so rain stays out of the brick and away from a liner.

Details

Dryer Vent Cleaning

Lint cleared from the dryer duct from the machine to the outside hood, with airflow checked once the dryer runs again.

Details

Chimney Liner Installation

Stainless steel liners run from the heater to the chimney top, sized to the insert, stove or gas unit they serve.

Details

Chimney Leak Repair

Water coming in at or around the chimney traced to crown, flashing, brick or cap, then repaired in the right place.

Details

Chimney Waterproofing

A breathable water repellent on clean, repaired brick, so rain beads off while moisture inside can still escape.

Details

Chimney Damper Repair

Throat dampers freed, reset or replaced, or a top-mount damper fitted, so the flue shuts tight when the fire is out.

Details
Call (323) 524-5311